Aleta.hr
Main Product Image

2CCS894001R0104 | S804N-C10

Code: 1548386

ManufacturerRAZNO
Catalog number2CCS894001R0104
Type
EAN code7612271204648

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Suitable for flush-mounted installation

No

Concurrently switching neutral conductor

No

Over voltage category

4

Additional equipment possible

Yes

Pollution degree

3

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Width in number of modular spacings

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Frequency

50 - 60Hz

Current limiting class

3

Connectable conductor cross section multi-wired

0 - 70mm²

Number of poles (total)

4

Connectable conductor cross section solid-core

0 - 50mm²

Built-in depth

82.5mm

Ambient temperature during operating

-25 - 60°C

Rated current

10A

Rated voltage

690V

Number of protected poles

4

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated insulation voltage Ui

690V


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCS894001R0104 | S804N-C10

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

4

Additional equipment possible

Pollution degree

3

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Width in number of modular spacings

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Frequency

50 .. 60Hz

Current limiting class

3

Connectable conductor cross section multi-wired

0 .. 70mm²

Number of poles (total)

4

Connectable conductor cross section solid-core

0 .. 50mm²

Built-in depth

82.5mm

Ambient temperature during operating

-25 .. 60°C

Rated current

10A

Rated voltage

690V

Number of protected poles

4

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated insulation voltage Ui

690V