Aleta.hr
Main Product Image

2CCS893001R0065 | S803N-B6

Code: 1548339

ManufacturerRAZNO
Catalog number2CCS893001R0065
Type
EAN code7612271408442

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

6A

Release characteristic

B

Number of protected poles

3

Rated insulation voltage Ui

690V

Rated voltage

690V

Number of poles (total)

3

Rated impulse withstand voltage Uimp

8kV

Voltage type

AC/DC

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Current limiting class

3

Concurrently switching neutral conductor

No

Suitable for flush-mounted installation

No

Pollution degree

3

Degree of protection (IP)

IP20

Built-in depth

82.5mm

Over voltage category

4

Additional equipment possible

Yes

Width in number of modular spacings

3

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section solid-core

0 - 50mm²

Connectable conductor cross section multi-wired

0 - 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA


Warehouse states

Zagreb:

1 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCS893001R0065 | S803N-B6

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

6A

Release characteristic

B

Number of protected poles

3

Rated insulation voltage Ui

690V

Rated voltage

690V

Number of poles (total)

3

Rated impulse withstand voltage Uimp

8kV

Voltage type

AC/DC

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Current limiting class

3

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Pollution degree

3

Degree of protection (IP)

IP20

Built-in depth

82.5mm

Over voltage category

4

Additional equipment possible

Width in number of modular spacings

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.