Aleta.hr
Main Product Image

2CCS863001R0405 | S803S-B40

Code: 1547754

ManufacturerRAZNO
Catalog number2CCS863001R0405
Type
EAN code7612271200305

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Current limiting class

3

Number of poles (total)

3

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Concurrently switching neutral conductor

No

Number of protected poles

3

Suitable for flush-mounted installation

No

Voltage type

AC/DC

Rated insulation voltage Ui

690V

Connectable conductor cross section solid-core

0 - 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated voltage

690V

Rated current

40A

Over voltage category

3

Rated impulse withstand voltage Uimp

8kV

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Built-in depth

88.5mm

Frequency

0 - 50Hz

Additional equipment possible

Yes

Ambient temperature during operating

-25 - 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 - 70mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCS863001R0405 | S803S-B40

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Current limiting class

3

Number of poles (total)

3

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Concurrently switching neutral conductor

Number of protected poles

3

Suitable for flush-mounted installation

Voltage type

AC/DC

Rated insulation voltage Ui

690V

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated voltage

690V

Rated current

40A

Over voltage category

3

Rated impulse withstand voltage Uimp

8kV

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Built-in depth

88.5mm

Frequency

0 .. 50Hz

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 70mm²