Aleta.hr
Main Product Image

2CCS861001R0577 | S801S-K50

Code: 1547446

ManufacturerRAZNO
Catalog number2CCS861001R0577
Type
EAN code7612271201517

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated impulse withstand voltage Uimp

8kV

Rated voltage

400V

Release characteristic

K

Number of poles (total)

1

Rated current

50A

Current limiting class

3

Voltage type

AC

Pollution degree

3

Frequency

50 - 60Hz

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Over voltage category

3

Additional equipment possible

Yes

Width in number of modular spacings

1

Connectable conductor cross section solid-core

0 - 50mm²

Suitable for flush-mounted installation

No

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Connectable conductor cross section multi-wired

0 - 70mm²

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Ambient temperature during operating

-25 - 60°C

Degree of protection (IP)

IP20

Rated insulation voltage Ui

690V


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCS861001R0577 | S801S-K50

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated impulse withstand voltage Uimp

8kV

Rated voltage

400V

Release characteristic

K

Number of poles (total)

1

Rated current

50A

Current limiting class

3

Voltage type

AC

Pollution degree

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Over voltage category

3

Additional equipment possible

Width in number of modular spacings

1

Connectable conductor cross section solid-core

0 .. 50mm²

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Rated insulation voltage Ui

690V

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.