![Main Product Image](https://assets.aleta.hr/415x415/d6da6fbc-2783-44c0-b66f-792da6fe239a.webp)
![Main Product Image](https://assets.aleta.hr/415x415/d6da6fbc-2783-44c0-b66f-792da6fe239a.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Rated voltage
220 - 690V
Overload release current setting
100.0 - 250A
Type of control element
Toggle
Complete device with protection unit
Yes
Number of poles
3
Integrated earth fault protection
No
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
No
Rated permanent current Iu
250A
Motor drive integrated
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
Adjustment range short-term delayed short-circuit release
250 - 2500A
Motor drive optional
Yes
Degree of protection (IP)
IP20
With under voltage release
No
Type of electrical connection of main circuit
Bolt connection
Position of connection for main current circuit
Front side
DIN rail (top hat rail) mounting optional
Yes
Adjustment range undelayed short-circuit release
250 - 2500A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA068136R1 | XT4N 250 EKIP LSI IN=250A 3P F F
![Main Product Image](https://assets.aleta.hr/300x300/68fca736-1612-46a7-a2e7-b07bf5a7a104_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Rated voltage
220 .. 690V
Overload release current setting
100.0 .. 250A
Type of control element
Toggle
Complete device with protection unit
Number of poles
3
Integrated earth fault protection
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Rated permanent current Iu
250A
Motor drive integrated
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
Adjustment range short-term delayed short-circuit release
250 .. 2500A
Motor drive optional
Degree of protection (IP)
IP20
With under voltage release
Type of electrical connection of main circuit
Bolt connection
Position of connection for main current circuit
Front side
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
250 .. 2500A