![Main Product Image](https://assets.aleta.hr/415x415/f35c89da-625f-4af8-982c-64c0d63b6132.webp)
![Main Product Image](https://assets.aleta.hr/415x415/f35c89da-625f-4af8-982c-64c0d63b6132.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Rated permanent current Iu
160A
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
Adjustment range undelayed short-circuit release
160 - 1600A
DIN rail (top hat rail) mounting optional
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
With under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Front side
Overload release current setting
64.0 - 160A
Integrated earth fault protection
No
With switched-off indicator
No
Number of poles
3
Rated voltage
220 - 690V
Type of control element
Toggle
Complete device with protection unit
Yes
Motor drive integrated
No
Adjustment range short-term delayed short-circuit release
160 - 1600A
Motor drive optional
Yes
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
1 pcs
Zadar:
0 pcs
From same serie
1SDA068125R1 | XT4N 160 EKIP LS/I IN=160A 3P F
![Main Product Image](https://assets.aleta.hr/300x300/7bc6dc17-7f0a-4062-8e05-2d2bf8766269_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Rated permanent current Iu
160A
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
Adjustment range undelayed short-circuit release
160 .. 1600A
DIN rail (top hat rail) mounting optional
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
With under voltage release
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Front side
Overload release current setting
64.0 .. 160A
Integrated earth fault protection
With switched-off indicator
Number of poles
3
Rated voltage
220 .. 690V
Type of control element
Toggle
Complete device with protection unit
Motor drive integrated
Adjustment range short-term delayed short-circuit release
160 .. 1600A
Motor drive optional
Degree of protection (IP)
IP20
From same serie