Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
100 - 1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
Rated permanent current Iu
160A
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
No
Overload release current setting
40.0 - 100A
Adjustment range short-term delayed short-circuit release
100 - 1000A
With under voltage release
No
DIN rail (top hat rail) mounting optional
Yes
Rated voltage
220 - 690V
With switched-off indicator
No
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Front side
Number of poles
3
Complete device with protection unit
Yes
Type of control element
Toggle
Motor drive optional
Yes
Degree of protection (IP)
IP20
Motor drive integrated
No
Warehouse states
Zagreb:
2 pcs
Zadar:
0 pcs
From same serie
1SDA068124R1 | XT4N 160 EKIP LS/I IN=100A 3P F
![Main Product Image](https://assets.aleta.hr/300x300/7bc6dc17-7f0a-4062-8e05-2d2bf8766269_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
100 .. 1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
Rated permanent current Iu
160A
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Overload release current setting
40.0 .. 100A
Adjustment range short-term delayed short-circuit release
100 .. 1000A
With under voltage release
DIN rail (top hat rail) mounting optional
Rated voltage
220 .. 690V
With switched-off indicator
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Front side
Number of poles
3
Complete device with protection unit
Type of control element
Toggle
Motor drive optional
Degree of protection (IP)
IP20
Motor drive integrated
From same serie