![Main Product Image](https://assets.aleta.hr/415x415/8b2e0bec-3c18-4598-a551-5f92cf2a5c23.webp)
![Main Product Image](https://assets.aleta.hr/415x415/8b2e0bec-3c18-4598-a551-5f92cf2a5c23.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Rated voltage
220 - 690V
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
160A
DIN rail (top hat rail) mounting optional
Yes
Device construction
Built-in device fixed built-in technique
Overload release current setting
22.4 - 32A
With under voltage release
No
Adjustment range undelayed short-circuit release
320 - 320A
With switched-off indicator
No
Number of poles
3
Position of connection for main current circuit
Front side
Suitable for DIN rail (top hat rail) mounting
No
Complete device with protection unit
Yes
Type of control element
Toggle
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
1 pcs
Zadar:
0 pcs
From same serie
1SDA067553R1 | XT2S 160 TMD 32-320 3P F F
![Main Product Image](https://assets.aleta.hr/300x300/20591f02-8f0c-4557-83e6-8cf758adbef6_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Rated voltage
220 .. 690V
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
160A
DIN rail (top hat rail) mounting optional
Device construction
Built-in device fixed built-in technique
Overload release current setting
22.4 .. 32A
With under voltage release
Adjustment range undelayed short-circuit release
320 .. 320A
With switched-off indicator
Number of poles
3
Position of connection for main current circuit
Front side
Suitable for DIN rail (top hat rail) mounting
Complete device with protection unit
Type of control element
Toggle
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP20
From same serie