Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
120kA
Rated permanent current Iu
1600A
Overload release current setting
640.0 - 1600A
Rated voltage
690 - 690V
DIN rail (top hat rail) mounting optional
No
Motor drive optional
No
Type of control element
Toggle
Number of poles
3
Device construction
Built-in device fixed built-in technique
Position of connection for main current circuit
Front side
Type of electrical connection of main circuit
Bolt connection
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
2400.0 - 19200A
With switched-off indicator
No
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
Degree of protection (IP)
IP20
Integrated earth fault protection
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA063060R1 | T7L 1600 PR331/P LSIG IN=1600A 3

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
120kA
Rated permanent current Iu
1600A
Overload release current setting
640.0 .. 1600A
Rated voltage
690 .. 690V
DIN rail (top hat rail) mounting optional
Motor drive optional
Type of control element
Toggle
Number of poles
3
Device construction
Built-in device fixed built-in technique
Position of connection for main current circuit
Front side
Type of electrical connection of main circuit
Bolt connection
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
2400.0 .. 19200A
With switched-off indicator
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Degree of protection (IP)
IP20
Integrated earth fault protection
From same serie