Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Type of electrical connection of main circuit
Bolt connection
Rated permanent current Iu
1000A
Adjustment range undelayed short-circuit release
1000 - 10000A
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range short-term delayed short-circuit release
1000 - 10000A
Type of control element
Toggle
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
No
Position of connection for main current circuit
Front side
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
No
With switched-off indicator
No
Complete device with protection unit
Yes
Number of poles
3
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
0
Overload release current setting
400.0 - 1000A
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
No
Degree of protection (IP)
IP20
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA062769R1 | T7H 1000 PR231/P I IN=1000A 3P F F

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Type of electrical connection of main circuit
Bolt connection
Rated permanent current Iu
1000A
Adjustment range undelayed short-circuit release
1000 .. 10000A
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
Adjustment range short-term delayed short-circuit release
1000 .. 10000A
Type of control element
Toggle
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
Position of connection for main current circuit
Front side
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
With switched-off indicator
Complete device with protection unit
Number of poles
3
Motor drive integrated
Number of auxiliary contacts as change-over contact
0
Overload release current setting
400.0 .. 1000A
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
Degree of protection (IP)
IP20
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
From same serie