Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1000A
Type of electrical connection of main circuit
Bolt connection
DIN rail (top hat rail) mounting optional
No
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Overload release current setting
400.0 - 1000A
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Integrated earth fault protection
No
Number of auxiliary contacts as normally closed contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Position of connection for main current circuit
Front side
Device construction
Built-in device fixed built-in technique
Number of poles
4
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
No
Motor drive optional
Yes
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Yes
Type of control element
Push button
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA062765R1 | T7S 1000 PR332/P LI IN=1000A 4P F F

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1000A
Type of electrical connection of main circuit
Bolt connection
DIN rail (top hat rail) mounting optional
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Overload release current setting
400.0 .. 1000A
Suitable for DIN rail (top hat rail) mounting
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Position of connection for main current circuit
Front side
Device construction
Built-in device fixed built-in technique
Number of poles
4
Motor drive integrated
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
Motor drive optional
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Type of control element
Push button
Degree of protection (IP)
IP20