Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Type of electrical connection of main circuit
Bolt connection
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Rated permanent current Iu
1000A
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Rated voltage
690 - 690V
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
With switched-off indicator
No
Overload release current setting
400.0 - 1000A
Number of poles
3
With under voltage release
No
DIN rail (top hat rail) mounting optional
No
Type of control element
Push button
Complete device with protection unit
Yes
Motor drive optional
Yes
Motor drive integrated
No
Degree of protection (IP)
IP20
Position of connection for main current circuit
Front side
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA062758R1 | T7S 1000 PR332/P LSI IN=1000A 3P F

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Type of electrical connection of main circuit
Bolt connection
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Rated permanent current Iu
1000A
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Rated voltage
690 .. 690V
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
With switched-off indicator
Overload release current setting
400.0 .. 1000A
Number of poles
3
With under voltage release
DIN rail (top hat rail) mounting optional
Type of control element
Push button
Complete device with protection unit
Motor drive optional
Motor drive integrated
Degree of protection (IP)
IP20
Position of connection for main current circuit
Front side