Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Integrated earth fault protection
No
Adjustment range undelayed short-circuit release
1200.0 - 9600A
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Type of electrical connection of main circuit
Bolt connection
Rated voltage
690 - 690V
Device construction
Built-in device fixed built-in technique
Rated permanent current Iu
800A
Suitable for DIN rail (top hat rail) mounting
No
Complete device with protection unit
Yes
Number of poles
4
Number of auxiliary contacts as change-over contact
0
Position of connection for main current circuit
Front side
With switched-off indicator
No
Motor drive integrated
No
DIN rail (top hat rail) mounting optional
No
Degree of protection (IP)
IP20
Overload release current setting
320.0 - 800A
Number of auxiliary contacts as normally open contact
0
Motor drive optional
No
Type of control element
Toggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Number of auxiliary contacts as normally closed contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA062715R1 | T7V 800 PR232/P LSI IN=800A 4P F F

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Integrated earth fault protection
Adjustment range undelayed short-circuit release
1200.0 .. 9600A
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Type of electrical connection of main circuit
Bolt connection
Rated voltage
690 .. 690V
Device construction
Built-in device fixed built-in technique
Rated permanent current Iu
800A
Suitable for DIN rail (top hat rail) mounting
Complete device with protection unit
Number of poles
4
Number of auxiliary contacts as change-over contact
0
Position of connection for main current circuit
Front side
With switched-off indicator
Motor drive integrated
DIN rail (top hat rail) mounting optional
Degree of protection (IP)
IP20
Overload release current setting
320.0 .. 800A
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Type of control element
Toggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Number of auxiliary contacts as normally closed contact
0
From same serie