Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
400.0 - 1000A
Integrated earth fault protection
No
Adjustment range short-term delayed short-circuit release
1000 - 10000A
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
1000 - 10000A
Type of electrical connection of main circuit
Bolt connection
With switched-off indicator
No
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Front side
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
No
Complete device with protection unit
Yes
Motor drive integrated
No
Device construction
Built-in device fixed built-in technique
Type of control element
Toggle
Number of auxiliary contacts as change-over contact
0
DIN rail (top hat rail) mounting optional
No
Number of poles
4
Motor drive optional
Yes
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA060580R1 | T6L 1000 PR221DS-LS/I IN=1000 4P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
400.0 .. 1000A
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
1000 .. 10000A
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
1000 .. 10000A
Type of electrical connection of main circuit
Bolt connection
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Front side
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
Complete device with protection unit
Motor drive integrated
Device construction
Built-in device fixed built-in technique
Type of control element
Toggle
Number of auxiliary contacts as change-over contact
0
DIN rail (top hat rail) mounting optional
Number of poles
4
Motor drive optional
Degree of protection (IP)
IP20