Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
No
Rated permanent current Iu
250A
Rated voltage
1150 - 1150V
Overload release current setting
100.0 - 250A
Adjustment range undelayed short-circuit release
375.0 - 3000A
Adjustment range short-term delayed short-circuit release
150.0 - 2500A
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Integrated earth fault protection
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Position of connection for main current circuit
Front side
With switched-off indicator
No
Type of control element
Toggle
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
Number of poles
3
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA054511R1 | T4L250 PR222DS/P-LSI IN=250 3P F FC CU

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
Rated permanent current Iu
250A
Rated voltage
1150 .. 1150V
Overload release current setting
100.0 .. 250A
Adjustment range undelayed short-circuit release
375.0 .. 3000A
Adjustment range short-term delayed short-circuit release
150.0 .. 2500A
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Position of connection for main current circuit
Front side
With switched-off indicator
Type of control element
Toggle
Complete device with protection unit
Motor drive integrated
Motor drive optional
Number of poles
3
Degree of protection (IP)
IP20
From same serie