Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
630A
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
378.0 - 6300A
Adjustment range undelayed short-circuit release
945.0 - 5985A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
No
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device fixed built-in technique
Rated voltage
690 - 690V
Type of electrical connection of main circuit
Bolt connection
Overload release current setting
252.0 - 630A
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
Yes
Number of poles
4
Position of connection for main current circuit
Front side
Motor drive integrated
No
Complete device with protection unit
Yes
Type of control element
Toggle
Degree of protection (IP)
IP20
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA054411R1 | T5S 630 PR222DS/P-LSIG IN=630 4P F F

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
630A
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
378.0 .. 6300A
Adjustment range undelayed short-circuit release
945.0 .. 5985A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
DIN rail (top hat rail) mounting optional
Device construction
Built-in device fixed built-in technique
Rated voltage
690 .. 690V
Type of electrical connection of main circuit
Bolt connection
Overload release current setting
252.0 .. 630A
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
Number of poles
4
Position of connection for main current circuit
Front side
Motor drive integrated
Complete device with protection unit
Type of control element
Toggle
Degree of protection (IP)
IP20
Motor drive optional
From same serie