Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Suitable for floor mounting
No
Suitable for intermediate mounting
No
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Number of switches
-
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Version as maintenance-/service switch
Yes
Version as safety switch
No
Version as emergency stop installation
No
Rated permanent current Iu
1000A
Version as reversing switch
No
Rated permanent current at AC-21, 400 V
1000A
Voltage release optional
No
Max. rated operation voltage Ue AC
1000V
Rated operating voltage
1000 - 1000V
Rated permanent current at AC-23, 400 V
1000A
Motor drive integrated
No
Rated operation power at AC-23, 400 V
560kW
Switching power at 400 V
560kW
Degree of protection (IP), front side
Other
Number of poles
3
Suitable for front mounting centre
No
Suitable for front mounting 4-hole
No
Device construction
Built-in device fixed built-in technique
Type of control element
None
Suitable for distribution board installation
Yes
Interlockable
No
Degree of protection (NEMA)
1
Version as main switch
Yes
Rated short-time withstand current lcw
50kA
Type of electrical connection of main circuit
Bolt connection
Motor drive optional
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SCA101547R1001 | OT1000E12

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Suitable for floor mounting
Suitable for intermediate mounting
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Number of switches
-
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Version as maintenance-/service switch
Version as safety switch
Version as emergency stop installation
Rated permanent current Iu
1000A
Version as reversing switch
Rated permanent current at AC-21, 400 V
1000A
Voltage release optional
Max. rated operation voltage Ue AC
1000V
Rated operating voltage
1000 .. 1000V
Rated permanent current at AC-23, 400 V
1000A
Motor drive integrated
Rated operation power at AC-23, 400 V
560kW
Switching power at 400 V
560kW
Degree of protection (IP), front side
Other
Number of poles
3
Suitable for front mounting centre
Suitable for front mounting 4-hole
Device construction
Built-in device fixed built-in technique
Type of control element
None
Suitable for distribution board installation
Interlockable
Degree of protection (NEMA)
1
Version as main switch
Rated short-time withstand current lcw
50kA
Type of electrical connection of main circuit
Bolt connection
Motor drive optional
From same serie