Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Suitable for floor mounting
No
Suitable for intermediate mounting
No
Suitable for distribution board installation
No
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Number of switches
-
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Rated permanent current at AC-21, 400 V
1600A
Rated permanent current at AC-23, 400 V
1250A
Max. rated operation voltage Ue AC
1000V
Version as emergency stop installation
No
Version as reversing switch
No
Version as maintenance-/service switch
Yes
Rated permanent current Iu
1600A
Version as main switch
Yes
Version as safety switch
No
Device construction
Built-in device fixed built-in technique
Switching power at 400 V
710kW
Motor drive integrated
No
Interlockable
No
Degree of protection (IP), front side
Other
Type of electrical connection of main circuit
Bolt connection
Voltage release optional
No
Motor drive optional
No
Type of control element
None
Number of poles
3
Rated operation power at AC-23, 400 V
710kW
Rated operating voltage
1000 - 1000V
Suitable for front mounting 4-hole
No
Suitable for front mounting centre
No
Rated short-time withstand current lcw
50kA
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SCA022860R6400 | OT1600E03

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Suitable for floor mounting
Suitable for intermediate mounting
Suitable for distribution board installation
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Number of switches
-
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Rated permanent current at AC-21, 400 V
1600A
Rated permanent current at AC-23, 400 V
1250A
Max. rated operation voltage Ue AC
1000V
Version as emergency stop installation
Version as reversing switch
Version as maintenance-/service switch
Rated permanent current Iu
1600A
Version as main switch
Version as safety switch
Device construction
Built-in device fixed built-in technique
Switching power at 400 V
710kW
Motor drive integrated
Interlockable
Degree of protection (IP), front side
Other
Type of electrical connection of main circuit
Bolt connection
Voltage release optional
Motor drive optional
Type of control element
None
Number of poles
3
Rated operation power at AC-23, 400 V
710kW
Rated operating voltage
1000 .. 1000V
Suitable for front mounting 4-hole
Suitable for front mounting centre
Rated short-time withstand current lcw
50kA
From same serie