Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Suitable for floor mounting
No
Suitable for intermediate mounting
No
Conditioned rated short-circuit current Iq
-kA
Number of switches
-
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Version as safety switch
No
Rated permanent current Iu
630A
Version as reversing switch
No
Rated permanent current at AC-23, 400 V
630A
Rated operating voltage
1000 - 1000V
Version as emergency stop installation
No
Rated short-time withstand current lcw
20kA
Rated permanent current at AC-21, 400 V
630A
Number of poles
3
Rated operation power at AC-23, 400 V
355kW
Voltage release optional
No
Suitable for front mounting 4-hole
No
Motor drive optional
No
Switching power at 400 V
355kW
Motor drive integrated
No
Suitable for distribution board installation
Yes
Max. rated operation voltage Ue AC
1000V
Type of control element
None
Degree of protection (NEMA)
1
Type of electrical connection of main circuit
Bolt connection
Interlockable
No
Degree of protection (IP), front side
Other
Device construction
Built-in device fixed built-in technique
Suitable for front mounting centre
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SCA022776R3120 | OT630E12

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Suitable for floor mounting
Suitable for intermediate mounting
Conditioned rated short-circuit current Iq
-kA
Number of switches
-
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Version as main switch
Version as maintenance-/service switch
Version as safety switch
Rated permanent current Iu
630A
Version as reversing switch
Rated permanent current at AC-23, 400 V
630A
Rated operating voltage
1000 .. 1000V
Version as emergency stop installation
Rated short-time withstand current lcw
20kA
Rated permanent current at AC-21, 400 V
630A
Number of poles
3
Rated operation power at AC-23, 400 V
355kW
Voltage release optional
Suitable for front mounting 4-hole
Motor drive optional
Switching power at 400 V
355kW
Motor drive integrated
Suitable for distribution board installation
Max. rated operation voltage Ue AC
1000V
Type of control element
None
Degree of protection (NEMA)
1
Type of electrical connection of main circuit
Bolt connection
Interlockable
Degree of protection (IP), front side
Other
Device construction
Built-in device fixed built-in technique
Suitable for front mounting centre