Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Suitable for floor mounting
No
Suitable for intermediate mounting
No
Conditioned rated short-circuit current Iq
-kA
Number of switches
-
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Version as main switch
Yes
Version as emergency stop installation
No
Version as safety switch
No
Version as maintenance-/service switch
Yes
Max. rated operation voltage Ue AC
1000V
Rated short-time withstand current lcw
20kA
Rated operating voltage
1000 - 1000V
Version as reversing switch
No
Rated permanent current at AC-21, 400 V
800A
Rated permanent current Iu
800A
Switching power at 400 V
450kW
Number of poles
4
Motor drive integrated
No
Device construction
Built-in device fixed built-in technique
Suitable for front mounting 4-hole
No
Motor drive optional
No
Type of control element
None
Suitable for front mounting centre
No
Voltage release optional
No
Suitable for distribution board installation
Yes
Interlockable
No
Rated operation power at AC-23, 400 V
450kW
Rated permanent current at AC-23, 400 V
800A
Degree of protection (NEMA)
1
Degree of protection (IP), front side
Other
Type of electrical connection of main circuit
Bolt connection
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SCA022753R5760 | OT800E04

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Suitable for floor mounting
Suitable for intermediate mounting
Conditioned rated short-circuit current Iq
-kA
Number of switches
-
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Version as main switch
Version as emergency stop installation
Version as safety switch
Version as maintenance-/service switch
Max. rated operation voltage Ue AC
1000V
Rated short-time withstand current lcw
20kA
Rated operating voltage
1000 .. 1000V
Version as reversing switch
Rated permanent current at AC-21, 400 V
800A
Rated permanent current Iu
800A
Switching power at 400 V
450kW
Number of poles
4
Motor drive integrated
Device construction
Built-in device fixed built-in technique
Suitable for front mounting 4-hole
Motor drive optional
Type of control element
None
Suitable for front mounting centre
Voltage release optional
Suitable for distribution board installation
Interlockable
Rated operation power at AC-23, 400 V
450kW
Rated permanent current at AC-23, 400 V
800A
Degree of protection (NEMA)
1
Degree of protection (IP), front side
Other
Type of electrical connection of main circuit
Bolt connection
From same serie