Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated short-time withstand current lcw
0.5kA
Switching power at 400 V
-kW
Rated permanent current at AC-23, 400 V
-A
Version as reversing switch
No
Version as maintenance-/service switch
No
Version as safety switch
No
Number of switches
2
Version as emergency stop installation
No
Version as main switch
No
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-21, 400 V
40A
Rated permanent current Iu
40A
Rated operation power at AC-23, 400 V
15kW
Rated operation power at AC-3, 400 V
11kW
Conditioned rated short-circuit current Iq
0kA
Number of poles
8
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Motor drive integrated
No
Motor drive optional
No
Voltage release optional
No
Rated operating voltage
690 - 690V
Device construction
Built-in device fixed built-in technique
Suitable for front mounting 4-hole
No
Suitable for front mounting centre
No
Suitable for distribution board installation
No
Colour control element
Other
Suitable for floor mounting
Yes
Suitable for intermediate mounting
No
Degree of protection (IP), front side
IP20
With pre-assembled cabling
No
Type of control element
Other
Type of electrical connection of main circuit
Screw connection
Interlockable
No
Degree of protection (NEMA)
Other
Height
90mm
Depth
125mm
Width
125mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
QM40/3N

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated short-time withstand current lcw
0.5kA
Switching power at 400 V
-kW
Rated permanent current at AC-23, 400 V
-A
Version as reversing switch
Version as maintenance-/service switch
Version as safety switch
Number of switches
2
Version as emergency stop installation
Version as main switch
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-21, 400 V
40A
Rated permanent current Iu
40A
Rated operation power at AC-23, 400 V
15kW
Rated operation power at AC-3, 400 V
11kW
Conditioned rated short-circuit current Iq
0kA
Number of poles
8
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Motor drive integrated
Motor drive optional
Voltage release optional
Rated operating voltage
690 .. 690V
Device construction
Built-in device fixed built-in technique
Suitable for front mounting 4-hole
Suitable for front mounting centre
Suitable for distribution board installation
Colour control element
Other
Suitable for floor mounting
Suitable for intermediate mounting
Degree of protection (IP), front side
IP20
With pre-assembled cabling
Type of control element
Other
Type of electrical connection of main circuit
Screw connection
Interlockable
Degree of protection (NEMA)
Other
Height
90mm
Depth
125mm
Width
125mm
From same serie