E55CBL12A2E
Code: 1201517
Code: 1201517
Width sensor
0mm
Height of sensor
0mm
Length of sensor
55mm
Diameter sensor
12mm
Mechanical mounting condition for sensor
Not flat
Switching distance
4mm
Type of switching output
2-wire
Type of switch function
Breaker contact
Type of electric connection
Cable
Number of semiconductor outputs with signalling function
1
Suitable for safety functions
No
Number of protected contact energized outputs
0
Number of protected semiconductor outputs
0
Type of interface for safety communication
None
Coating housing
Other
Performance level according to EN ISO 13849-1
None
Max. output current at protected output
0mA
SIL according to IEC 61508
None
Rated control supply voltage Us at AC 50HZ
20 - 250V
Supply voltage
20 - 250V
Rated control supply voltage Us at DC
0 - 0V
Construction type housing
Cylinder, screw-thread
Cascadable
No
Voltage type
AC
Number of contact energized outputs with signalling function
0
Explosion safety category for gas
None
Switching frequency
25Hz
Type of actuation
Metallic Target
Type of interface
None
Compression-resistant
No
With monitoring function downstream switching devices
No
Material housing
Plastic
Explosion safety category for dust
None
Rated control supply voltage Us at AC 60HZ
20 - 250V
Degree of protection (NEMA)
4X, 13
Zagreb:
0 pcs
Zadar:
0 pcs
E55CBL12A2E
Width sensor
0mm
Height of sensor
0mm
Length of sensor
55mm
Diameter sensor
12mm
Mechanical mounting condition for sensor
Not flat
Switching distance
4mm
Type of switching output
2-wire
Type of switch function
Breaker contact
Type of electric connection
Cable
Number of semiconductor outputs with signalling function
1
Suitable for safety functions
Number of protected contact energized outputs
0
Number of protected semiconductor outputs
0
Type of interface for safety communication
None
Coating housing
Other
Performance level according to EN ISO 13849-1
None
Max. output current at protected output
0mA
SIL according to IEC 61508
None
Rated control supply voltage Us at AC 50HZ
20 .. 250V
Supply voltage
20 .. 250V
Rated control supply voltage Us at DC
0 .. 0V
Construction type housing
Cylinder, screw-thread
Cascadable
Voltage type
AC
Number of contact energized outputs with signalling function
0
Explosion safety category for gas
None
Switching frequency
25Hz
Type of actuation
Metallic Target
Type of interface
None
Compression-resistant
With monitoring function downstream switching devices
Material housing
Plastic
Explosion safety category for dust
None
Rated control supply voltage Us at AC 60HZ
20 .. 250V
Degree of protection (NEMA)
4X, 13
We use cookies to enhance your experience.