E52Q-DL35UAD01
Code: 1201423
Code: 1201423
Voltage type
DC
Material housing
Plastic
Rated control supply voltage Us at DC
6 - 48V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated control supply voltage Us at AC 50HZ
0 - 0V
Type of electric connection
Connector M12
Explosion safety category for dust
None
Length of sensor
40mm
Explosion safety category for gas
None
Height of sensor
40mm
Width sensor
40mm
Type of interface
None
Diameter sensor
0mm
Construction type housing
Cuboid
Coating housing
Other
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
With monitoring function downstream switching devices
No
Category according to EN 954-1
B
Number of protected semiconductor outputs
0
Supply voltage
6 - 48V
Number of semiconductor outputs with signalling function
1
Type of switching output
Other
Number of contact energized outputs with signalling function
0
Type of switch function
Anticoincidence
Max. output current at protected output
0mA
Suitable for safety functions
No
Type of interface for safety communication
None
Number of protected contact energized outputs
0
Switching frequency
100Hz
Type of actuation
Metallic Target
Compression-resistant
No
Mechanical mounting condition for sensor
Not flat
Cascadable
No
Switching distance
35mm
Zagreb:
0 pcs
Zadar:
0 pcs
E52Q-DL35UAD01
Voltage type
DC
Material housing
Plastic
Rated control supply voltage Us at DC
6 .. 48V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Type of electric connection
Connector M12
Explosion safety category for dust
None
Length of sensor
40mm
Explosion safety category for gas
None
Height of sensor
40mm
Width sensor
40mm
Type of interface
None
Diameter sensor
0mm
Construction type housing
Cuboid
Coating housing
Other
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
With monitoring function downstream switching devices
Category according to EN 954-1
B
Number of protected semiconductor outputs
0
Supply voltage
6 .. 48V
Number of semiconductor outputs with signalling function
1
Type of switching output
Other
Number of contact energized outputs with signalling function
0
Type of switch function
Anticoincidence
Max. output current at protected output
0mA
Suitable for safety functions
Type of interface for safety communication
None
Number of protected contact energized outputs
0
Switching frequency
100Hz
Type of actuation
Metallic Target
Compression-resistant
Mechanical mounting condition for sensor
Not flat
Cascadable
Switching distance
35mm