- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at AC 50HZ
0 - 0V
With short-circuit release
Yes
Type of motor starter
Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase
3kW
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 - 24V
Rated operation power at AC-3, 400 V
5.5kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current at AC-3, 400 V
12A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
11.3A
Overload release current setting
3 - 12A
Rated conditional short-circuit current, type 2, 400 V
100000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated conditional short-circuit current, type 2, 230 V
100000A
Number of auxiliary contacts as normally open contact
0
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Width
45mm
Height
242mm
Depth
128mm
Number of auxiliary contacts as normally closed contact
1
Ambient temperature, upper operating limit
55°C
Temperature compensated overload protection
Yes
Release class
Adjustable
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Rail mounting possible
No
Number of command positions
0
With transformer
No
Suitable for emergency stop
No
Number of indicator lights
0
External reset possible
No
With fuse
No
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Supporting protocol for TCP/IP
No
Supporting protocol for INTERBUS
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for CAN
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for SERCOS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Foundation Fieldbus
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
MSC-DEA-12-M17(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at AC 50HZ
0 .. 0V
With short-circuit release
Type of motor starter
Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase
3kW
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 .. 24V
Rated operation power at AC-3, 400 V
5.5kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current at AC-3, 400 V
12A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
11.3A
Overload release current setting
3 .. 12A
Rated conditional short-circuit current, type 2, 400 V
100000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated conditional short-circuit current, type 2, 230 V
100000A
Number of auxiliary contacts as normally open contact
0
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
45mm
Height
242mm
Depth
128mm
Number of auxiliary contacts as normally closed contact
1
Ambient temperature, upper operating limit
55°C
Temperature compensated overload protection
Release class
Adjustable
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Rail mounting possible
Number of command positions
0
With transformer
Suitable for emergency stop
Number of indicator lights
0
External reset possible
With fuse
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for CAN
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
From same serie