Aleta.hr
Main Product Image

MSC-DE-4-M7(230V50HZ)

Code: 1090860

ManufacturerRAZNO
Catalog number121737
Type
EAN code4015081195473

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated conditional short-circuit current, type 2, 400 V

100A

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Yes

Rated control supply voltage Us at AC 50HZ

230 - 230V

Rated operation power at AC-3, 230 V, 3-phase

0.75kW

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated operation power at AC-3, 400 V

1.5kW

Rated control supply voltage Us at DC

0 - 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

AC

Overload release current setting

1 - 4A

Rated operation current Ie

3.6A

Number of auxiliary contacts as normally open contact

1

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation current at AC-3, 400 V

4A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Number of auxiliary contacts as normally closed contact

0

Rated conditional short-circuit current, type 2, 230 V

0A

Ambient temperature, upper operating limit

55°C

Rail mounting possible

No

Type of electrical connection of main circuit

Screw connection

Release class

Adjustable

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Number of command positions

0

Temperature compensated overload protection

Yes

With fuse

No

With transformer

No

Coordination class according to IEC 60947-4-3

Class 1

Number of indicator lights

0

External reset possible

No

Supporting protocol for CAN

No

Supporting protocol for PROFIBUS

No

Supporting protocol for TCP/IP

No

Supporting protocol for Modbus

No

Supporting protocol for INTERBUS

No

Degree of protection (NEMA)

Other

Degree of protection (IP)

IP20

Suitable for emergency stop

No

Supporting protocol for ASI

No

Supporting protocol for DeviceNet

No

Supporting protocol for SERCOS

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for SUCONET

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for LON

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for PROFINET IO

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for Data-Highway

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

No

Width

45mm

Height

198mm

Depth

102mm


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-DE-4-M7(230V50HZ)

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated conditional short-circuit current, type 2, 400 V

100A

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated operation power at AC-3, 230 V, 3-phase

0.75kW

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation power at AC-3, 400 V

1.5kW

Rated control supply voltage Us at DC

0 .. 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

AC

Overload release current setting

1 .. 4A

Rated operation current Ie

3.6A

Number of auxiliary contacts as normally open contact

1

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation current at AC-3, 400 V

4A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Number of auxiliary contacts as normally closed contact

0

Rated conditional short-circuit current, type 2, 230 V

0A

Ambient temperature, upper operating limit

55°C

Rail mounting possible

Type of electrical connection of main circuit

Screw connection

Release class

Adjustable

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Number of command positions

0

Temperature compensated overload protection

With fuse

With transformer

Coordination class according to IEC 60947-4-3

Class 1

Number of indicator lights

0

External reset possible

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Degree of protection (NEMA)

Other

Degree of protection (IP)

IP20

Suitable for emergency stop

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for SUCONET

Supporting protocol for DeviceNet Safety

Supporting protocol for LON

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

45mm

Height

198mm

Depth

102mm

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.