Aleta.hr
Main Product Image

MSC-DE-32-M17(24VDC)

Code: 1090855

ManufacturerRAZNO
Catalog number121748
Type
EAN code4015081195589

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With short-circuit release

Yes

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 50HZ

0 - 0V

Rated control supply voltage Us at AC 60HZ

0 - 0V

Voltage type for actuating

DC

Rated control supply voltage Us at DC

24 - 24V

Rated operation power at AC-3, 230 V, 3-phase

4kW

Overload release current setting

8 - 32A

Rated operation power at AC-3, 400 V

7.5kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

17A

Rated operation current Ie

16.7A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 2, 230 V

100000A

Temperature compensated overload protection

Yes

Number of auxiliary contacts as normally closed contact

0

Release class

Adjustable

Rated conditional short-circuit current, type 2, 400 V

100000A

Ambient temperature, upper operating limit

55°C

With transformer

No

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

External reset possible

No

Number of command positions

0

Suitable for emergency stop

No

Rail mounting possible

No

Number of indicator lights

0

Degree of protection (IP)

IP20

Coordination class according to IEC 60947-4-3

Class 2

Supporting protocol for PROFIBUS

No

With fuse

No

Supporting protocol for TCP/IP

No

Degree of protection (NEMA)

Other

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for CAN

No

Supporting protocol for Modbus

No

Supporting protocol for DeviceNet

No

Supporting protocol for Data-Highway

No

Supporting protocol for ASI

No

Supporting protocol for INTERBUS

No

Supporting protocol for LON

No

Supporting protocol for SERCOS

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for PROFINET IO

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for SUCONET

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

No

Width

45mm

Height

242mm

Depth

128mm


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-DE-32-M17(24VDC)

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With short-circuit release

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Voltage type for actuating

DC

Rated control supply voltage Us at DC

24 .. 24V

Rated operation power at AC-3, 230 V, 3-phase

4kW

Overload release current setting

8 .. 32A

Rated operation power at AC-3, 400 V

7.5kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

17A

Rated operation current Ie

16.7A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 2, 230 V

100000A

Temperature compensated overload protection

Number of auxiliary contacts as normally closed contact

0

Release class

Adjustable

Rated conditional short-circuit current, type 2, 400 V

100000A

Ambient temperature, upper operating limit

55°C

With transformer

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

External reset possible

Number of command positions

0

Suitable for emergency stop

Rail mounting possible

Number of indicator lights

0

Degree of protection (IP)

IP20

Coordination class according to IEC 60947-4-3

Class 2

Supporting protocol for PROFIBUS

With fuse

Supporting protocol for TCP/IP

Degree of protection (NEMA)

Other

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for SUCONET

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

45mm

Height

242mm

Depth

128mm

From same serie