Details
- Cable carrying systems
- Vertical cable ladder
- 1 M
- OBO
Technical specifications
Material quality
Other
Colour
None
Surface protection
Hot-dip galvanized
Material
Steel
RAL-number
-
Length
3000mm
Suitable for circuit integrity
No
Stainless steel, pickled
No
Side wall perforation
Yes
Useful cross section
-mm²
Type of rung
Imperforated profile
Type of side wall
U-profile
Rung distance
600mm
Height cable ladder
50mm
Width cable ladder
700mm
Rung centre spacing
600mm
Height
50mm
Working length
-mm
Width
700mm
Vertical cable ladder
Yes
Weight
7.11kg/m
Operating temperature
- - -°C
Possible support spacing
- - -m
Safe working load according to IEC 61537 with support spacing 0.5 m
-N/m
Safe working load according to IEC 61537 with support spacing 1.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 2.5 m
-N/m
Safe working load according to IEC 61537 with support spacing 1.5 m
-N/m
Safe working load according to IEC 61537 with support spacing 3.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 6.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 2.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 4.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 5.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 8.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 12.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 7.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 9.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 11.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 10.0 m
-N/m
Warehouse states
Zagreb:
0 M
Zadar:
0 M
Related products
From same serie
6010512 | SLM 50 C40 7 FT

Details
- Cable carrying systems
- Vertical cable ladder
- 1 M
- OBO
Technical specifications
Material quality
Other
Colour
None
Surface protection
Hot-dip galvanized
Material
Steel
RAL-number
-
Length
3000mm
Suitable for circuit integrity
Stainless steel, pickled
Side wall perforation
Useful cross section
-mm²
Type of rung
Imperforated profile
Type of side wall
U-profile
Rung distance
600mm
Height cable ladder
50mm
Width cable ladder
700mm
Rung centre spacing
600mm
Height
50mm
Working length
-mm
Width
700mm
Vertical cable ladder
Weight
7.11kg/m
Operating temperature
- .. -°C
Possible support spacing
- .. -m
Safe working load according to IEC 61537 with support spacing 0.5 m
-N/m
Safe working load according to IEC 61537 with support spacing 1.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 2.5 m
-N/m
Safe working load according to IEC 61537 with support spacing 1.5 m
-N/m
Safe working load according to IEC 61537 with support spacing 3.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 6.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 2.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 4.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 5.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 8.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 12.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 7.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 9.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 11.0 m
-N/m
Safe working load according to IEC 61537 with support spacing 10.0 m
-N/m
From same serie
Related products
We use cookies to enhance your experience.