- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- OBO
Technical specifications
System configuration DC
No
System configuration IT
No
System configuration TN
No
System configuration TN-C
No
System configuration TN-C-S
No
System configuration TN-S
No
System configuration TT
No
System configuration other
No
Number of conductors (without earthing)
-
Nominal discharge surge current (8/20)
20kA
Max. discharge surge current (8/20)
25kA
Nominal voltage AC
-V
Nominal voltage DC
-V
Max. continuous voltage AC
385V
Max. continuous voltage DC
-V
Max. PV-voltage
-V
Voltage protection level
1.8kV
Voltage protection level L-N
-kV
Max. overcurrent protection device, parallel connection (fuse)
-A
Max. overcurrent protection device, series connection (fuse)
-A
Voltage protection level N-PE
-kV
Short-circuit breaking capacity (Isccr)
-kA
Integrated short-circuit protection
No
Integrated short-circuit protection selective to fuse gG
-A
Integrated backup fuse
No
Leakage-current free
No
Mounting method
On basic element
Construction size
1 modular spacing
Max. conductor cross section solid (solid, stranded)
-mm²
Max. conductor cross section flexible (fine-strand)
-mm²
With remote signalling contact
No
Signalling at the device
Optic
Category type 2
No
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
5099613 | V20-VA 0

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- OBO
Technical specifications
System configuration DC
System configuration IT
System configuration TN
System configuration TN-C
System configuration TN-C-S
System configuration TN-S
System configuration TT
System configuration other
Number of conductors (without earthing)
-
Nominal discharge surge current (8/20)
20kA
Max. discharge surge current (8/20)
25kA
Nominal voltage AC
-V
Nominal voltage DC
-V
Max. continuous voltage AC
385V
Max. continuous voltage DC
-V
Max. PV-voltage
-V
Voltage protection level
1.8kV
Voltage protection level L-N
-kV
Max. overcurrent protection device, parallel connection (fuse)
-A
Max. overcurrent protection device, series connection (fuse)
-A
Voltage protection level N-PE
-kV
Short-circuit breaking capacity (Isccr)
-kA
Integrated short-circuit protection
Integrated short-circuit protection selective to fuse gG
-A
Integrated backup fuse
Leakage-current free
Mounting method
On basic element
Construction size
1 modular spacing
Max. conductor cross section solid (solid, stranded)
-mm²
Max. conductor cross section flexible (fine-strand)
-mm²
With remote signalling contact
Signalling at the device
Optic
Category type 2
Degree of protection (IP)
IP20