Details
- Earthing, lightning and surge protection
- Lightning current arrester for power supply systems
- 1 KOM
- OBO
Technical specifications
System configuration TN
No
System configuration TN-C-S
No
Number of conductors (without earthing)
-
Max. continuous voltage DC
-V
Lightning impulse current (10/350 µs)
150kA
System configuration DC
No
Voltage protection level L-N
-kV
System configuration other
No
Max. continuous voltage AC
255V
Nominal voltage DC
-V
Voltage protection level
2kV
System configuration TN-C
No
Voltage protection level N-PE
-kV
System configuration IT
No
System configuration TN-S
No
Nominal discharge surge current (8/20)
125kA
Nominal voltage AC
230V
System configuration TT
No
Voltage protection level (DC+/DC- - PE)
-kV
Specific energy (W/R)
-kJ/Ohm
Max. conductor cross section solid (solid, stranded)
-mm²
Max. conductor cross section flexible (fine-strand)
-mm²
Integrated backup fuse
No
Signalling at the device
None
Mounting method
DIN rail (top hat rail) 35 mm
Exhausting
No
Construction size
6 modular spacing
Category type 1
Yes
With remote signalling contact
No
Suitable for outdoor use
No
Voltage protection level (DC+ - DC-)
-kV
Follow current extinguishing capability
25kA
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
5096876 | MC 50-B 3

Details
- Earthing, lightning and surge protection
- Lightning current arrester for power supply systems
- 1 KOM
- OBO
Technical specifications
System configuration TN
System configuration TN-C-S
Number of conductors (without earthing)
-
Max. continuous voltage DC
-V
Lightning impulse current (10/350 µs)
150kA
System configuration DC
Voltage protection level L-N
-kV
System configuration other
Max. continuous voltage AC
255V
Nominal voltage DC
-V
Voltage protection level
2kV
System configuration TN-C
Voltage protection level N-PE
-kV
System configuration IT
System configuration TN-S
Nominal discharge surge current (8/20)
125kA
Nominal voltage AC
230V
System configuration TT
Voltage protection level (DC+/DC- - PE)
-kV
Specific energy (W/R)
-kJ/Ohm
Max. conductor cross section solid (solid, stranded)
-mm²
Max. conductor cross section flexible (fine-strand)
-mm²
Integrated backup fuse
Signalling at the device
None
Mounting method
DIN rail (top hat rail) 35 mm
Exhausting
Construction size
6 modular spacing
Category type 1
With remote signalling contact
Suitable for outdoor use
Voltage protection level (DC+ - DC-)
-kV
Follow current extinguishing capability
25kA
From same serie