Details
- Earthing, lightning and surge protection
- Lightning current arrester for power supply systems
- 1 KOM
- OBO
Technical specifications
System configuration DC
No
System configuration IT
No
System configuration TN-C
No
System configuration TN-S
No
Number of conductors (without earthing)
-
Nominal discharge surge current (8/20)
125kA
System configuration other
No
System configuration TN-C-S
No
Nominal voltage DC
-V
Max. continuous voltage AC
255V
System configuration TT
No
Lightning impulse current (10/350 µs)
125kA
System configuration TN
No
Voltage protection level L-N
-kV
Max. continuous voltage DC
-V
Voltage protection level N-PE
-kV
Nominal voltage AC
-V
Voltage protection level
2kV
Construction size
2 modular spacing
Max. conductor cross section flexible (fine-strand)
-mm²
Follow current extinguishing capability
-kA
Mounting method
DIN rail (top hat rail) 35 mm
Voltage protection level (DC+/DC- - PE)
-kV
Exhausting
No
Max. conductor cross section solid (solid, stranded)
-mm²
Integrated backup fuse
No
Category type 1
Yes
Signalling at the device
None
Specific energy (W/R)
-kJ/Ohm
Suitable for outdoor use
No
Voltage protection level (DC+ - DC-)
-kV
With remote signalling contact
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
5096839 | MC 50-B U VDE

Details
- Earthing, lightning and surge protection
- Lightning current arrester for power supply systems
- 1 KOM
- OBO
Technical specifications
System configuration DC
System configuration IT
System configuration TN-C
System configuration TN-S
Number of conductors (without earthing)
-
Nominal discharge surge current (8/20)
125kA
System configuration other
System configuration TN-C-S
Nominal voltage DC
-V
Max. continuous voltage AC
255V
System configuration TT
Lightning impulse current (10/350 µs)
125kA
System configuration TN
Voltage protection level L-N
-kV
Max. continuous voltage DC
-V
Voltage protection level N-PE
-kV
Nominal voltage AC
-V
Voltage protection level
2kV
Construction size
2 modular spacing
Max. conductor cross section flexible (fine-strand)
-mm²
Follow current extinguishing capability
-kA
Mounting method
DIN rail (top hat rail) 35 mm
Voltage protection level (DC+/DC- - PE)
-kV
Exhausting
Max. conductor cross section solid (solid, stranded)
-mm²
Integrated backup fuse
Category type 1
Signalling at the device
None
Specific energy (W/R)
-kJ/Ohm
Suitable for outdoor use
Voltage protection level (DC+ - DC-)
-kV
With remote signalling contact