Technical specifications
Switching current
8A
Supply voltage AC 50 Hz
0 - 0V
Number of analogue inputs
0
Voltage type of supply voltage
DC
Power consumption
6W
Number of analogue outputs
4
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces Wireless
0
Number of digital outputs
4
With relay output
Yes
Number of interfaces PROFINET
0
Supply voltage DC
20.4 - 28.8V
Number of digital inputs
14
With optical interface
No
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces other
3
Supporting protocol for ASI
No
Supply voltage AC 60 Hz
0 - 0V
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
0
Supporting protocol for KNX
No
Supporting protocol for TCP/IP
No
Supporting protocol for INTERBUS
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for PROFIBUS
No
Supporting protocol for LON
No
Supporting protocol for EtherCAT
No
Supporting protocol for DeviceNet
No
Number of HW-interfaces RS-232
1
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for other bus systems
Yes
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for SUCONET
No
Number of HW-interfaces USB
0
Supporting protocol for PROFINET IO
No
Supporting protocol for CAN
No
IO link master
No
Redundancy
Yes
With display
No
Degree of protection (IP)
IP20
Basic device
Yes
Expandable
Yes
Rail mounting possible
Yes
With time switch clock
Yes
Wall mounting/direct mounting
Yes
Front built-in possible
No
Rack-assembly possible
No
SIL according to IEC 61508
3
Suitable for safety functions
Yes
Expansion device
No
Performance level according to EN ISO 13849-1
Level e
Radio standard GSM
No
Appendant operation agent (Ex ib)
No
Appendant operation agent (Ex ia)
No
Explosion safety category for gas
None
Radio standard Bluetooth
No
Certified for UL hazardous location class I
No
Explosion safety category for dust
None
Certified for UL hazardous location class III
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Width
108mm
Height
90mm
Depth
72mm
Certified for UL hazardous location group G (non-conductive dusts)
No
Radio standard GPRS
No
Radio standard UMTS
No
Radio standard Wi-Fi 802.11
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
ES4P-221-DRXX1

Details
- Programmable logic controllers PLC
- Logic module
- 1 KOM
- EATON
Technical specifications
Switching current
8A
Supply voltage AC 50 Hz
0 .. 0V
Number of analogue inputs
0
Voltage type of supply voltage
DC
Power consumption
6W
Number of analogue outputs
4
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces Wireless
0
Number of digital outputs
4
With relay output
Number of interfaces PROFINET
0
Supply voltage DC
20.4 .. 28.8V
Number of digital inputs
14
With optical interface
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces other
3
Supporting protocol for ASI
Supply voltage AC 60 Hz
0 .. 0V
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
0
Supporting protocol for KNX
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for PROFIBUS
Supporting protocol for LON
Supporting protocol for EtherCAT
Supporting protocol for DeviceNet
Number of HW-interfaces RS-232
1
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for other bus systems
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for SUCONET
Number of HW-interfaces USB
0
Supporting protocol for PROFINET IO
Supporting protocol for CAN
IO link master
Redundancy
With display
Degree of protection (IP)
IP20
Basic device
Expandable
Rail mounting possible
With time switch clock
Wall mounting/direct mounting
Front built-in possible
Rack-assembly possible
SIL according to IEC 61508
3
Suitable for safety functions
Expansion device
Performance level according to EN ISO 13849-1
Level e
Radio standard GSM
Appendant operation agent (Ex ib)
Appendant operation agent (Ex ia)
Explosion safety category for gas
None
Radio standard Bluetooth
Certified for UL hazardous location class I
Explosion safety category for dust
None
Certified for UL hazardous location class III
Certified for UL hazardous location division 2
Certified for UL hazardous location division 1
Certified for UL hazardous location class II
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Width
108mm
Height
90mm
Depth
72mm
Certified for UL hazardous location group G (non-conductive dusts)
Radio standard GPRS
Radio standard UMTS
Radio standard Wi-Fi 802.11
From same serie