Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - communication module
- 1 KOM
- EATON
Technical specifications
Voltage type of supply voltage
DC
Number of HW-interfaces industrial Ethernet
0
Supply voltage AC 50 Hz
0 - 0V
Number of HW-interfaces RS-485
0
Number of interfaces PROFINET
0
Supply voltage DC
20.4 - 28.8V
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Supply voltage AC 60 Hz
0 - 0V
Number of HW-interfaces RS-232
1
Supporting protocol for TCP/IP
No
Number of HW-interfaces CAN
1
Number of HW-interfaces Wireless
0
Supporting protocol for PROFIBUS
No
Supporting protocol for INTERBUS
No
Supporting protocol for CAN
No
Supporting protocol for ASI
No
Supporting protocol for DeviceNet
No
Supporting protocol for KNX
No
Supporting protocol for EtherCAT
No
Supporting protocol for SUCONET
No
Supporting protocol for Data-Highway
No
Supporting protocol for SERCOS
No
Supporting protocol for Modbus
No
Number of HW-interfaces other
0
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Radio standard Wi-Fi 802.11
No
Radio standard GPRS
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for INTERBUS-Safety
No
Radio standard Bluetooth
No
Supporting protocol for other bus systems
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFIsafe
No
Radio standard eGPRS
No
Rail mounting possible
Yes
Wall mounting/direct mounting
Yes
Supporting protocol for AS-Interface Safety at Work
No
Front built-in possible
No
Rack-assembly possible
No
Suitable for safety functions
Yes
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location class III
No
Radio standard GSM
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group C (ethylene)
No
IO link master
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Width
35mm
Depth
127mm
Height
90mm
Radio standard UMTS
No
With potential separation
No
Degree of protection (IP)
IP20
Fieldbus connection over separate bus coupler possible
No
System accessory
Yes
Radio standard LTE
No
Related products
From same serie
EU5C-SWD-CAN

Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - communication module
- 1 KOM
- EATON
Technical specifications
Voltage type of supply voltage
DC
Number of HW-interfaces industrial Ethernet
0
Supply voltage AC 50 Hz
0 .. 0V
Number of HW-interfaces RS-485
0
Number of interfaces PROFINET
0
Supply voltage DC
20.4 .. 28.8V
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Supply voltage AC 60 Hz
0 .. 0V
Number of HW-interfaces RS-232
1
Supporting protocol for TCP/IP
Number of HW-interfaces CAN
1
Number of HW-interfaces Wireless
0
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for DeviceNet
Supporting protocol for KNX
Supporting protocol for EtherCAT
Supporting protocol for SUCONET
Supporting protocol for Data-Highway
Supporting protocol for SERCOS
Supporting protocol for Modbus
Number of HW-interfaces other
0
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Radio standard Wi-Fi 802.11
Radio standard GPRS
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
Supporting protocol for INTERBUS-Safety
Radio standard Bluetooth
Supporting protocol for other bus systems
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFIsafe
Radio standard eGPRS
Rail mounting possible
Wall mounting/direct mounting
Supporting protocol for AS-Interface Safety at Work
Front built-in possible
Rack-assembly possible
Suitable for safety functions
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Explosion safety category for gas
None
Explosion safety category for dust
None
Certified for UL hazardous location class I
Certified for UL hazardous location class II
Certified for UL hazardous location division 1
Certified for UL hazardous location division 2
Certified for UL hazardous location class III
Radio standard GSM
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group C (ethylene)
IO link master
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Width
35mm
Depth
127mm
Height
90mm
Radio standard UMTS
With potential separation
Degree of protection (IP)
IP20
Fieldbus connection over separate bus coupler possible
System accessory
Radio standard LTE
From same serie
Related products
We use cookies to enhance your experience.