Technical specifications
Supply voltage AC 50 Hz
0 - 0V
Supply voltage DC
20.4 - 28.8V
Supply voltage AC 60 Hz
0 - 0V
With optical interface
No
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Voltage type of supply voltage
DC
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces Wireless
0
Supporting protocol for PROFIBUS
No
Supporting protocol for EtherCAT
No
Supporting protocol for INTERBUS
No
Number of HW-interfaces other
1
Supporting protocol for Data-Highway
No
Number of interfaces PROFINET
0
Supporting protocol for ASI
No
Supporting protocol for CAN
No
Supporting protocol for DeviceNet
No
Supporting protocol for LON
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFINET CBA
No
Radio standard Bluetooth
No
Supporting protocol for EtherNet/IP
No
Radio standard Wi-Fi 802.11
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for other bus systems
Yes
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for TCP/IP
No
Radio standard GPRS
No
Radio standard UMTS
No
Radio standard GSM
No
Fieldbus connection over separate bus coupler possible
Yes
Bus diagnosis possible
No
Wall mounting/direct mounting
Yes
Rail mounting possible
Yes
Rack-assembly possible
No
Front built-in possible
No
Suitable for safety functions
No
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
No
Performance level according to EN ISO 13849-1
None
Explosion safety category for gas
None
Explosion safety category for dust
None
Certified for UL hazardous location class II
No
Certified for UL hazardous location class I
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location class III
No
Appendant operation agent (Ex ib)
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Height
90mm
Depth
125mm
Width
35mm
Degree of protection (IP)
IP20
Type of electric connection
Flat plug-in connection
With potential separation
No
System accessory
Yes
With power supply module
Yes
Remote module
No
Suitable as segment module
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
EU5C-SWD-PF1-1

Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - power supply/segment module
- 1 KOM
- EATON
Technical specifications
Supply voltage AC 50 Hz
0 .. 0V
Supply voltage DC
20.4 .. 28.8V
Supply voltage AC 60 Hz
0 .. 0V
With optical interface
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Voltage type of supply voltage
DC
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces Wireless
0
Supporting protocol for PROFIBUS
Supporting protocol for EtherCAT
Supporting protocol for INTERBUS
Number of HW-interfaces other
1
Supporting protocol for Data-Highway
Number of interfaces PROFINET
0
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for KNX
Supporting protocol for Modbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET CBA
Radio standard Bluetooth
Supporting protocol for EtherNet/IP
Radio standard Wi-Fi 802.11
Supporting protocol for PROFIsafe
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for SafetyBUS p
Supporting protocol for DeviceNet Safety
Supporting protocol for other bus systems
Supporting protocol for INTERBUS-Safety
Supporting protocol for TCP/IP
Radio standard GPRS
Radio standard UMTS
Radio standard GSM
Fieldbus connection over separate bus coupler possible
Bus diagnosis possible
Wall mounting/direct mounting
Rail mounting possible
Rack-assembly possible
Front built-in possible
Suitable for safety functions
SIL according to IEC 61508
None
Appendant operation agent (Ex ia)
Performance level according to EN ISO 13849-1
None
Explosion safety category for gas
None
Explosion safety category for dust
None
Certified for UL hazardous location class II
Certified for UL hazardous location class I
Certified for UL hazardous location division 1
Certified for UL hazardous location class III
Appendant operation agent (Ex ib)
Certified for UL hazardous location division 2
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Height
90mm
Depth
125mm
Width
35mm
Degree of protection (IP)
IP20
Type of electric connection
Flat plug-in connection
With potential separation
System accessory