Details
- Low-voltage industrial components
- Combination of contactors
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at AC 60HZ
0 - 0V
Function
Reversing contactor
Rated control supply voltage Us at DC
24 - 24V
Rated control supply voltage Us at AC 50HZ
0 - 0V
Number of normally open contacts as main contact
6
Type of electrical connection of main circuit
Screw connection
Voltage type for actuating
DC
Rail mounting possible
No
Operating voltage at AC 50 Hz
24 - 690V
Voltage type (operating voltage)
AC
Number of normally closed contacts as main contact
0
Operating voltage at AC 60 Hz
24 - 690V
Operating voltage at DC
0 - 0V
Rated operation current Ie at AC-3, 400 V
12A
Rated operation current Ie at AC-1, 400 V
12A
Number of auxiliary contacts as normally closed contact
0
Rated operation power at AC-3, 400 V
5.5kW
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of auxiliary contacts as change-over contact
0
Rated operation power NEMA
7.4kW
Width
90mm
Number of auxiliary contacts as normally open contact
2
Degree of protection (IP)
IP20
Depth
117mm
Height
68mm
Degree of protection (NEMA)
Other
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DIULM12/21(24VDC)

Details
- Low-voltage industrial components
- Combination of contactors
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Function
Reversing contactor
Rated control supply voltage Us at DC
24 .. 24V
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Number of normally open contacts as main contact
6
Type of electrical connection of main circuit
Screw connection
Voltage type for actuating
DC
Rail mounting possible
Operating voltage at AC 50 Hz
24 .. 690V
Voltage type (operating voltage)
AC
Number of normally closed contacts as main contact
0
Operating voltage at AC 60 Hz
24 .. 690V
Operating voltage at DC
0 .. 0V
Rated operation current Ie at AC-3, 400 V
12A
Rated operation current Ie at AC-1, 400 V
12A
Number of auxiliary contacts as normally closed contact
0
Rated operation power at AC-3, 400 V
5.5kW
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of auxiliary contacts as change-over contact
0
Rated operation power NEMA
7.4kW
Width
90mm
Number of auxiliary contacts as normally open contact
2
Degree of protection (IP)
IP20
Depth
117mm
Height
68mm
Degree of protection (NEMA)
Other
From same serie
Related products
We use cookies to enhance your experience.