Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Yes
Version as reversing switch
No
Version as safety switch
No
Version as maintenance-/service switch
Yes
Rated permanent current Iu
250A
Max. rated operation voltage Ue AC
690V
Rated operating voltage
690 - 690V
Switching power at 400 V
0kW
Rated short-time withstand current lcw
3.5kA
Number of switches
1
Version as emergency stop installation
Yes
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
No
Rated operation power at AC-3, 400 V
0kW
Number of auxiliary contacts as normally open contact
0
Rated permanent current at AC-23, 400 V
0A
Rated permanent current at AC-21, 400 V
0A
Rated operation power at AC-23, 400 V
132kW
Motor drive integrated
No
Number of poles
3
Conditioned rated short-circuit current Iq
0kA
Number of auxiliary contacts as change-over contact
0
Suitable for front mounting 4-hole
No
Colour control element
Black
Suitable for front mounting centre
No
Suitable for floor mounting
Yes
Suitable for intermediate mounting
Yes
Type of control element
Rocker lever
Width
105mm
Interlockable
Yes
Voltage release optional
No
Type of electrical connection of main circuit
Frame clamp
With pre-assembled cabling
No
Height
184mm
Degree of protection (IP), front side
IP20
Device construction
Built-in device fixed built-in technique
Depth
149mm
Suitable for distribution board installation
Yes
Related products
From same serie
PN2-250-BT

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Version as reversing switch
Version as safety switch
Version as maintenance-/service switch
Rated permanent current Iu
250A
Max. rated operation voltage Ue AC
690V
Rated operating voltage
690 .. 690V
Switching power at 400 V
0kW
Rated short-time withstand current lcw
3.5kA
Number of switches
1
Version as emergency stop installation
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Rated operation power at AC-3, 400 V
0kW
Number of auxiliary contacts as normally open contact
0
Rated permanent current at AC-23, 400 V
0A
Rated permanent current at AC-21, 400 V
0A
Rated operation power at AC-23, 400 V
132kW
Motor drive integrated
Number of poles
3
Conditioned rated short-circuit current Iq
0kA
Number of auxiliary contacts as change-over contact
0
Suitable for front mounting 4-hole
Colour control element
Black
Suitable for front mounting centre
Suitable for floor mounting
Suitable for intermediate mounting
Type of control element
Rocker lever
Width
105mm
Interlockable
Voltage release optional
Type of electrical connection of main circuit
Frame clamp
With pre-assembled cabling
Height
184mm
Degree of protection (IP), front side
IP20
Device construction
Built-in device fixed built-in technique
Depth
149mm
Suitable for distribution board installation
From same serie
Related products