Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Overload release current setting
315 - 630A
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
0 - 0A
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Screw connection
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
1260 - 5040A
With switched-off indicator
No
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Position of connection for main current circuit
Front side
Integrated earth fault protection
Yes
Device construction
Built-in device fixed built-in technique
Complete device with protection unit
Yes
Motor drive integrated
No
Type of control element
Rocker lever
With integrated under voltage release
No
Degree of protection (IP)
IP20
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
NZMN3-AE630-T

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Overload release current setting
315 .. 630A
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
0 .. 0A
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Screw connection
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
1260 .. 5040A
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Position of connection for main current circuit
Front side
Integrated earth fault protection
Device construction
Built-in device fixed built-in technique
Complete device with protection unit
Motor drive integrated
Type of control element
Rocker lever
With integrated under voltage release
Degree of protection (IP)
IP20
Motor drive optional
From same serie