Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Integrated earth fault protection
No
Overload release current setting
200 - 400A
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Type of electrical connection of main circuit
Screw connection
With switched-off indicator
No
Adjustment range undelayed short-circuit release
800 - 4400A
Adjustment range short-term delayed short-circuit release
400 - 4000A
Rated permanent current Iu
400A
DIN rail (top hat rail) mounting optional
No
With integrated under voltage release
No
Type of control element
Rocker lever
Position of connection for main current circuit
Front side
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
NZMH3-VE400-AVE

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Integrated earth fault protection
Overload release current setting
200 .. 400A
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Type of electrical connection of main circuit
Screw connection
With switched-off indicator
Adjustment range undelayed short-circuit release
800 .. 4400A
Adjustment range short-term delayed short-circuit release
400 .. 4000A
Rated permanent current Iu
400A
DIN rail (top hat rail) mounting optional
With integrated under voltage release
Type of control element
Rocker lever
Position of connection for main current circuit
Front side
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Motor drive integrated
Motor drive optional
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Degree of protection (IP)
IP20
From same serie
Related products
We use cookies to enhance your experience.