

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Adjustment range short-term delayed short-circuit release
0 - 0A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device fixed built-in technique
Integrated earth fault protection
Yes
Number of poles
3
Rated permanent current Iu
630A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
DIN rail (top hat rail) mounting optional
No
Overload release current setting
315 - 630A
Adjustment range undelayed short-circuit release
1260 - 5040A
Type of control element
Rocker lever
Position of connection for main current circuit
Front side
With integrated under voltage release
No
Motor drive optional
Yes
Type of electrical connection of main circuit
Screw connection
With switched-off indicator
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP20
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
NZMH3-AE630-T

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Adjustment range short-term delayed short-circuit release
0 .. 0A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device fixed built-in technique
Integrated earth fault protection
Number of poles
3
Rated permanent current Iu
630A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
DIN rail (top hat rail) mounting optional
Overload release current setting
315 .. 630A
Adjustment range undelayed short-circuit release
1260 .. 5040A
Type of control element
Rocker lever
Position of connection for main current circuit
Front side
With integrated under voltage release
Motor drive optional
Type of electrical connection of main circuit
Screw connection
With switched-off indicator
Complete device with protection unit
Degree of protection (IP)
IP20
Motor drive integrated
From same serie
Related products
We use cookies to enhance your experience.