Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
250A
Rated voltage
690 - 690V
Degree of protection (IP)
IP20
DIN rail (top hat rail) mounting optional
Yes
With switched-off indicator
No
Adjustment range undelayed short-circuit release
2000 - 2500A
Number of poles
3
Type of electrical connection of main circuit
Screw connection
Integrated earth fault protection
No
Type of control element
Rocker lever
With integrated under voltage release
No
Number of auxiliary contacts as change-over contact
0
Suitable for DIN rail (top hat rail) mounting
No
Motor drive integrated
No
Adjustment range short-term delayed short-circuit release
250 - 2500A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
125 - 250A
Complete device with protection unit
Yes
Device construction
Built-in device plug-in technique
Motor drive optional
Yes
Position of connection for main current circuit
Front side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
NZMH2-VE250-SVE

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
250A
Rated voltage
690 .. 690V
Degree of protection (IP)
IP20
DIN rail (top hat rail) mounting optional
With switched-off indicator
Adjustment range undelayed short-circuit release
2000 .. 2500A
Number of poles
3
Type of electrical connection of main circuit
Screw connection
Integrated earth fault protection
Type of control element
Rocker lever
With integrated under voltage release
Number of auxiliary contacts as change-over contact
0
Suitable for DIN rail (top hat rail) mounting
Motor drive integrated
Adjustment range short-term delayed short-circuit release
250 .. 2500A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
125 .. 250A
Complete device with protection unit
Device construction
Built-in device plug-in technique
Motor drive optional
Position of connection for main current circuit
Front side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
From same serie
Related products