Details
- Sensors
- End switch
- 1 KOM
- EATON
Technical specifications
Width sensor
30mm
Length of sensor
33.35mm
Diameter sensor
0mm
Height of sensor
96mm
Rated operation current Ie at AC-15, 24 V
10A
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 125 V
6A
Rated operation current Ie at DC-13, 24 V
3A
Rated operation current Ie at AC-15, 230 V
6A
Rated operation current Ie at DC-13, 230 V
0.3A
Rated operation current Ie at DC-13, 125 V
0.8A
Number of safety auxiliary contacts
1
Material housing
Plastic
Type of interface for safety communication
None
Output electronic
No
Number of contacts as normally closed contact
1
Forced opening
Yes
Number of contacts as normally open contact
1
Switching function latching
No
Number of contacts as change-over contact
0
Coating housing
Other
Alignment of the control element
Other
Type of interface
None
Degree of protection (IP)
IP66
Type of electric connection
Cable entry metrical
Type of control element
Other
Construction type housing
Cuboid
Explosion safety category for dust
None
Explosion safety category for gas
None
Suitable for safety functions
Yes
Ambient temperature during operating
-25 - 70°C
With status indication
No
Degree of protection (NEMA)
Other
Related products
From same serie
LS-S11S-ZB

Details
- Sensors
- End switch
- 1 KOM
- EATON
Technical specifications
Width sensor
30mm
Length of sensor
33.35mm
Diameter sensor
0mm
Height of sensor
96mm
Rated operation current Ie at AC-15, 24 V
10A
Switching function
Quick-break switch
Rated operation current Ie at AC-15, 125 V
6A
Rated operation current Ie at DC-13, 24 V
3A
Rated operation current Ie at AC-15, 230 V
6A
Rated operation current Ie at DC-13, 230 V
0.3A
Rated operation current Ie at DC-13, 125 V
0.8A
Number of safety auxiliary contacts
1
Material housing
Plastic
Type of interface for safety communication
None
Output electronic
Number of contacts as normally closed contact
1
Forced opening
Number of contacts as normally open contact
1
Switching function latching
Number of contacts as change-over contact
0
Coating housing
Other
Alignment of the control element
Other
Type of interface
None
Degree of protection (IP)
IP66
Type of electric connection
Cable entry metrical
Type of control element
Other
Construction type housing
Cuboid
Explosion safety category for dust
None
Explosion safety category for gas
None
Suitable for safety functions
Ambient temperature during operating
-25 .. 70°C
With status indication
Degree of protection (NEMA)
Other
From same serie