Details
- Sensors
- End switch
- 1 KOM
- EATON
Technical specifications
Height of sensor
96mm
Diameter sensor
0mm
Width sensor
30mm
Rated operation current Ie at AC-15, 125 V
6A
Rated operation current Ie at AC-15, 230 V
6A
Length of sensor
33.35mm
Rated operation current Ie at DC-13, 230 V
0.3A
Rated operation current Ie at DC-13, 24 V
3A
Switching function latching
No
Rated operation current Ie at DC-13, 125 V
0.8A
Switching function
Slow-action switch
Output electronic
No
Rated operation current Ie at AC-15, 24 V
10A
Number of contacts as normally open contact
0
Explosion safety category for dust
None
Type of interface
None
Construction type housing
Cuboid
Number of safety auxiliary contacts
2
Number of contacts as normally closed contact
2
Type of control element
Other
Number of contacts as change-over contact
0
Alignment of the control element
Other
Material housing
Plastic
Explosion safety category for gas
None
Forced opening
Yes
With status indication
No
Suitable for safety functions
Yes
Type of interface for safety communication
None
Type of electric connection
Cable entry metrical
Ambient temperature during operating
-25 - 70°C
Coating housing
Other
Degree of protection (NEMA)
Other
Degree of protection (IP)
IP66
Related products
From same serie
LS-S02-ZB

Details
- Sensors
- End switch
- 1 KOM
- EATON
Technical specifications
Height of sensor
96mm
Diameter sensor
0mm
Width sensor
30mm
Rated operation current Ie at AC-15, 125 V
6A
Rated operation current Ie at AC-15, 230 V
6A
Length of sensor
33.35mm
Rated operation current Ie at DC-13, 230 V
0.3A
Rated operation current Ie at DC-13, 24 V
3A
Switching function latching
Rated operation current Ie at DC-13, 125 V
0.8A
Switching function
Slow-action switch
Output electronic
Rated operation current Ie at AC-15, 24 V
10A
Number of contacts as normally open contact
0
Explosion safety category for dust
None
Type of interface
None
Construction type housing
Cuboid
Number of safety auxiliary contacts
2
Number of contacts as normally closed contact
2
Type of control element
Other
Number of contacts as change-over contact
0
Alignment of the control element
Other
Material housing
Plastic
Explosion safety category for gas
None
Forced opening
With status indication
Suitable for safety functions
Type of interface for safety communication
None
Type of electric connection
Cable entry metrical
Ambient temperature during operating
-25 .. 70°C
Coating housing
Other
Degree of protection (NEMA)
Other
Degree of protection (IP)
IP66
From same serie
Related products
We use cookies to enhance your experience.