Details
- Low-voltage industrial components
- Combination of contactors
- 1 KOM
- EATON
Technical specifications
Function
Star-delta contactor
Rated control supply voltage Us at AC 50HZ
400 - 400V
Rail mounting possible
No
Operating voltage at AC 60 Hz
24 - 690V
Type of electrical connection of main circuit
Screw connection
Rated control supply voltage Us at DC
0 - 0V
Voltage type (operating voltage)
AC
Number of normally open contacts as main contact
9
Number of normally closed contacts as main contact
0
Operating voltage at DC
0 - 0V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated operation power at AC-3, 400 V
11kW
Voltage type for actuating
AC
Operating voltage at AC 50 Hz
24 - 690V
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated operation current Ie at AC-1, 400 V
22A
Rated operation current Ie at AC-3, 400 V
22A
Number of auxiliary contacts as change-over contact
0
Degree of protection (NEMA)
Other
Height
82mm
Number of auxiliary contacts as normally open contact
3
Rated operation power NEMA
0kW
Width
158mm
Degree of protection (IP)
IP20
Depth
117mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
SDAINLM22(400V50HZ)

Details
- Low-voltage industrial components
- Combination of contactors
- 1 KOM
- EATON
Technical specifications
Function
Star-delta contactor
Rated control supply voltage Us at AC 50HZ
400 .. 400V
Rail mounting possible
Operating voltage at AC 60 Hz
24 .. 690V
Type of electrical connection of main circuit
Screw connection
Rated control supply voltage Us at DC
0 .. 0V
Voltage type (operating voltage)
AC
Number of normally open contacts as main contact
9
Number of normally closed contacts as main contact
0
Operating voltage at DC
0 .. 0V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated operation power at AC-3, 400 V
11kW
Voltage type for actuating
AC
Operating voltage at AC 50 Hz
24 .. 690V
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated operation current Ie at AC-1, 400 V
22A
Rated operation current Ie at AC-3, 400 V
22A
Number of auxiliary contacts as change-over contact
0
Degree of protection (NEMA)
Other
Height
82mm
Number of auxiliary contacts as normally open contact
3
Rated operation power NEMA
0kW
Width
158mm
Degree of protection (IP)
IP20
Depth
117mm