Details
- Low-voltage industrial components
- Combination of contactors
- 1 KOM
- EATON
Technical specifications
Rail mounting possible
No
Function
Star-delta contactor
Rated control supply voltage Us at AC 50HZ
400 - 400V
Voltage type for actuating
AC
Rated control supply voltage Us at DC
0 - 0V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Number of normally closed contacts as main contact
0
Number of normally open contacts as main contact
9
Operating voltage at AC 50 Hz
24 - 690V
Rated operation current Ie at AC-1, 400 V
16A
Type of electrical connection of main circuit
Screw connection
Operating voltage at DC
0 - 0V
Voltage type (operating voltage)
AC
Rated operation power at AC-3, 400 V
7.5kW
Degree of protection (NEMA)
Other
Rated operation current Ie at AC-3, 400 V
16A
Rated operation power NEMA
0kW
Height
82mm
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Operating voltage at AC 60 Hz
24 - 690V
Number of auxiliary contacts as normally open contact
3
Depth
117mm
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Width
158mm
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
SDAINLM16(400V50HZ)

Details
- Low-voltage industrial components
- Combination of contactors
- 1 KOM
- EATON
Technical specifications
Rail mounting possible
Function
Star-delta contactor
Rated control supply voltage Us at AC 50HZ
400 .. 400V
Voltage type for actuating
AC
Rated control supply voltage Us at DC
0 .. 0V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Number of normally closed contacts as main contact
0
Number of normally open contacts as main contact
9
Operating voltage at AC 50 Hz
24 .. 690V
Rated operation current Ie at AC-1, 400 V
16A
Type of electrical connection of main circuit
Screw connection
Operating voltage at DC
0 .. 0V
Voltage type (operating voltage)
AC
Rated operation power at AC-3, 400 V
7.5kW
Degree of protection (NEMA)
Other
Rated operation current Ie at AC-3, 400 V
16A
Rated operation power NEMA
0kW
Height
82mm
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Operating voltage at AC 60 Hz
24 .. 690V
Number of auxiliary contacts as normally open contact
3
Depth
117mm
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Width
158mm
Degree of protection (IP)
IP20