Details
- Low-voltage industrial components
- Combination of contactors
- 1 KOM
- EATON
Technical specifications
Function
Star-delta contactor
Number of normally open contacts as main contact
9
Rated operation current Ie at AC-3, 400 V
12A
Rail mounting possible
No
Number of normally closed contacts as main contact
0
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally closed contact
0
Voltage type for actuating
AC
Rated control supply voltage Us at AC 50HZ
400 - 400V
Operating voltage at AC 50 Hz
24 - 690V
Voltage type (operating voltage)
AC
Number of auxiliary contacts as normally open contact
3
Operating voltage at DC
0 - 0V
Operating voltage at AC 60 Hz
24 - 690V
Rated operation power at AC-3, 400 V
5.5kW
Rated operation current Ie at AC-1, 400 V
12A
Rated operation power NEMA
0kW
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Height
82mm
Width
158mm
Number of auxiliary contacts as change-over contact
0
Degree of protection (IP)
IP20
Rated control supply voltage Us at DC
0 - 0V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Degree of protection (NEMA)
Other
Depth
117mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
SDAINLM12(400V50HZ)

Details
- Low-voltage industrial components
- Combination of contactors
- 1 KOM
- EATON
Technical specifications
Function
Star-delta contactor
Number of normally open contacts as main contact
9
Rated operation current Ie at AC-3, 400 V
12A
Rail mounting possible
Number of normally closed contacts as main contact
0
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally closed contact
0
Voltage type for actuating
AC
Rated control supply voltage Us at AC 50HZ
400 .. 400V
Operating voltage at AC 50 Hz
24 .. 690V
Voltage type (operating voltage)
AC
Number of auxiliary contacts as normally open contact
3
Operating voltage at DC
0 .. 0V
Operating voltage at AC 60 Hz
24 .. 690V
Rated operation power at AC-3, 400 V
5.5kW
Rated operation current Ie at AC-1, 400 V
12A
Rated operation power NEMA
0kW
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Height
82mm
Width
158mm
Number of auxiliary contacts as change-over contact
0
Degree of protection (IP)
IP20
Rated control supply voltage Us at DC
0 .. 0V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Degree of protection (NEMA)
Other
Depth
117mm