Aleta.hr
Main Product Image

FAZ-B10/3

Code: 1047297

ManufacturerRAZNO
Catalog number278843
Type
EAN code4015082788438

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

3

Release characteristic

B

Built-in depth

70.5mm

Rated voltage

400V

Rated current

10A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Power loss

5.5W

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Concurrently switching neutral conductor

No

Pollution degree

2

Degree of protection (IP)

IP20

Over voltage category

3

Flush-mounted installation

No

Additional equipment possible

Yes

Ambient temperature during operating

-25 - 75°C

Explosion-proof

No

Connectable conductor cross section multi-wired

1 - 25mm²

Connectable conductor cross section solid-core

1 - 25mm²

Width in number of modular spacings

3

Number of protected poles

3


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


Related products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

FAZ-B10/3

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

3

Release characteristic

B

Built-in depth

70.5mm

Rated voltage

400V

Rated current

10A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Power loss

5.5W

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Concurrently switching neutral conductor

Pollution degree

2

Degree of protection (IP)

IP20

Over voltage category

3

Flush-mounted installation

Additional equipment possible

Ambient temperature during operating

-25 .. 75°C

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Width in number of modular spacings

3

Number of protected poles

3