Aleta.hr
Main Product Image

FAZ-K20/2

Code: 1047268

ManufacturerRAZNO
Catalog number278799
Type
EAN code4015082787998

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Number of protected poles

3

Number of poles (total)

1

Release characteristic

K

Rated voltage

400V

Rated current

20A

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

No

Power loss

8W

Additional equipment possible

Yes

Rated impulse withstand voltage Uimp

4kV

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Width in number of modular spacings

1

Frequency

50 - 60Hz

Explosion-proof

No

Ambient temperature during operating

-25 - 75°C

Over voltage category

3

Connectable conductor cross section multi-wired

1 - 25mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 - 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Flush-mounted installation

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


Related products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

FAZ-K20/2

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Number of protected poles

3

Number of poles (total)

1

Release characteristic

K

Rated voltage

400V

Rated current

20A

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Power loss

8W

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Width in number of modular spacings

1

Frequency

50 .. 60Hz

Explosion-proof

Ambient temperature during operating

-25 .. 75°C

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Flush-mounted installation