

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Reversing starter
Rated control supply voltage Us at DC
0 - 0V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated operation power at AC-3, 400 V
4kW
Rated operation current Ie
8.5A
Overload release current setting
6.3 - 10A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
Voltage type for actuating
AC
Rated power, 460 V, 60 Hz, 3-phase
0kW
Number of auxiliary contacts as normally closed contact
0
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Power consumption
1.4W
Rated conditional short-circuit current, type 2, 400 V
150A
Suitable for emergency stop
No
Number of indicator lights
0
Rated conditional short-circuit current, type 2, 230 V
0A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
No
Rated control supply voltage Us at AC 50HZ
230 - 230V
Rail mounting possible
No
Number of command positions
0
With fuse
No
Release class
CLASS 10 A
Ambient temperature, upper operating limit
55°C
Temperature compensated overload protection
Yes
Coordination class according to IEC 60947-4-3
Class 1
Type of electrical connection of main circuit
Screw connection
Rated operation current at AC-3, 400 V
9A
With short-circuit release
Yes
Number of auxiliary contacts as normally open contact
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
External reset possible
No
Degree of protection (IP)
IP20
Supporting protocol for CAN
No
Degree of protection (NEMA)
Other
Supporting protocol for PROFIBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for SUCONET
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for LON
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for Modbus
No
Width
90mm
Supporting protocol for other bus systems
No
Height
95mm
Depth
185mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
MSC-R-10-M9(230V50HZ)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Reversing starter
Rated control supply voltage Us at DC
0 .. 0V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated operation power at AC-3, 400 V
4kW
Rated operation current Ie
8.5A
Overload release current setting
6.3 .. 10A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
Voltage type for actuating
AC
Rated power, 460 V, 60 Hz, 3-phase
0kW
Number of auxiliary contacts as normally closed contact
0
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Power consumption
1.4W
Rated conditional short-circuit current, type 2, 400 V
150A
Suitable for emergency stop
Number of indicator lights
0
Rated conditional short-circuit current, type 2, 230 V
0A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rail mounting possible
Number of command positions
0
With fuse
Release class
CLASS 10 A
Ambient temperature, upper operating limit
55°C
Temperature compensated overload protection
Coordination class according to IEC 60947-4-3
Class 1
Type of electrical connection of main circuit
Screw connection
Rated operation current at AC-3, 400 V
9A
With short-circuit release
Number of auxiliary contacts as normally open contact
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
External reset possible
Degree of protection (IP)
IP20
Supporting protocol for CAN
Degree of protection (NEMA)
Other
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Supporting protocol for TCP/IP
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for SUCONET
Supporting protocol for Foundation Fieldbus
Supporting protocol for LON
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for Modbus
Width
90mm
Supporting protocol for other bus systems
Height
95mm
Depth
185mm
From same serie
We use cookies to enhance your experience.