Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated operation power at AC-3, 400 V
2.2kW
Number of auxiliary contacts as normally open contact
0
Rated operation current Ie
5A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated control supply voltage Us at AC 50HZ
230 - 230V
Voltage type for actuating
AC
Type of motor starter
Reversing starter
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated operation current at AC-3, 400 V
6.3A
With short-circuit release
Yes
Power consumption
1.4W
Release class
CLASS 10 A
Overload release current setting
4 - 6.3A
Ambient temperature, upper operating limit
55°C
Rated control supply voltage Us at DC
0 - 0V
Number of auxiliary contacts as normally closed contact
0
Rated power, 460 V, 60 Hz, 3-phase
0kW
Temperature compensated overload protection
Yes
Number of command positions
0
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rail mounting possible
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
With transformer
No
Suitable for emergency stop
No
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for other bus systems
No
Supporting protocol for SafetyBUS p
No
Width
90mm
Supporting protocol for PROFIsafe
No
Height
95mm
Depth
185mm
External reset possible
No
With fuse
No
Number of indicator lights
0
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Supporting protocol for INTERBUS
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for Modbus
No
Supporting protocol for ASI
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
MSC-R-6,3-M7(230V50HZ)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated operation power at AC-3, 400 V
2.2kW
Number of auxiliary contacts as normally open contact
0
Rated operation current Ie
5A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Voltage type for actuating
AC
Type of motor starter
Reversing starter
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated operation current at AC-3, 400 V
6.3A
With short-circuit release
Power consumption
1.4W
Release class
CLASS 10 A
Overload release current setting
4 .. 6.3A
Ambient temperature, upper operating limit
55°C
Rated control supply voltage Us at DC
0 .. 0V
Number of auxiliary contacts as normally closed contact
0
Rated power, 460 V, 60 Hz, 3-phase
0kW
Temperature compensated overload protection
Number of command positions
0
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rail mounting possible
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
With transformer
Suitable for emergency stop
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Width
90mm
Supporting protocol for PROFIsafe
Height
95mm
Depth
185mm
External reset possible
With fuse
Number of indicator lights
0
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for Modbus
Supporting protocol for ASI
Supporting protocol for PROFINET IO
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
From same serie