Aleta.hr
Main Product Image

MSC-R-6,3-M7(230V50HZ)

Code: 1046677

ManufacturerRAZNO
Catalog number283181
Type
EAN code4015082831813

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated operation power at AC-3, 400 V

2.2kW

Number of auxiliary contacts as normally open contact

0

Rated operation current Ie

5A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated control supply voltage Us at AC 50HZ

230 - 230V

Voltage type for actuating

AC

Type of motor starter

Reversing starter

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated operation current at AC-3, 400 V

6.3A

With short-circuit release

Yes

Power consumption

1.4W

Release class

CLASS 10 A

Overload release current setting

4 - 6.3A

Ambient temperature, upper operating limit

55°C

Rated control supply voltage Us at DC

0 - 0V

Number of auxiliary contacts as normally closed contact

0

Rated power, 460 V, 60 Hz, 3-phase

0kW

Temperature compensated overload protection

Yes

Number of command positions

0

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Rail mounting possible

No

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

With transformer

No

Suitable for emergency stop

No

Coordination class according to IEC 60947-4-3

Class 2

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for other bus systems

No

Supporting protocol for SafetyBUS p

No

Width

90mm

Supporting protocol for PROFIsafe

No

Height

95mm

Depth

185mm

External reset possible

No

With fuse

No

Number of indicator lights

0

Degree of protection (IP)

IP20

Degree of protection (NEMA)

Other

Supporting protocol for INTERBUS

No

Supporting protocol for TCP/IP

No

Supporting protocol for PROFIBUS

No

Supporting protocol for CAN

No

Supporting protocol for Modbus

No

Supporting protocol for ASI

No

Supporting protocol for PROFINET IO

No

Supporting protocol for Data-Highway

No

Supporting protocol for DeviceNet

No

Supporting protocol for SUCONET

No

Supporting protocol for LON

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for SERCOS

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-R-6,3-M7(230V50HZ)

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated operation power at AC-3, 400 V

2.2kW

Number of auxiliary contacts as normally open contact

0

Rated operation current Ie

5A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Voltage type for actuating

AC

Type of motor starter

Reversing starter

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated operation current at AC-3, 400 V

6.3A

With short-circuit release

Power consumption

1.4W

Release class

CLASS 10 A

Overload release current setting

4 .. 6.3A

Ambient temperature, upper operating limit

55°C

Rated control supply voltage Us at DC

0 .. 0V

Number of auxiliary contacts as normally closed contact

0

Rated power, 460 V, 60 Hz, 3-phase

0kW

Temperature compensated overload protection

Number of command positions

0

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Rail mounting possible

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

With transformer

Suitable for emergency stop

Coordination class according to IEC 60947-4-3

Class 2

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Supporting protocol for SafetyBUS p

Width

90mm

Supporting protocol for PROFIsafe

Height

95mm

Depth

185mm

External reset possible

With fuse

Number of indicator lights

0

Degree of protection (IP)

IP20

Degree of protection (NEMA)

Other

Supporting protocol for INTERBUS

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for ASI

Supporting protocol for PROFINET IO

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.