Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated operation power at AC-3, 230 V, 3-phase
0.09kW
Rated control supply voltage Us at DC
0 - 0V
With short-circuit release
Yes
Rated control supply voltage Us at AC 50HZ
230 - 230V
Type of motor starter
Reversing starter
Voltage type for actuating
AC
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
0.6A
Power consumption
1.4W
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
0.63A
Rated conditional short-circuit current, type 2, 400 V
50000A
Overload release current setting
0.4 - 0.63A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 230 V
50000A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Number of indicator lights
0
Supporting protocol for TCP/IP
No
Coordination class according to IEC 60947-4-3
Class 2
With fuse
No
Supporting protocol for SUCONET
No
External reset possible
No
Supporting protocol for PROFIBUS
No
Degree of protection (NEMA)
Other
Number of command positions
0
Suitable for emergency stop
No
Supporting protocol for ASI
No
Release class
CLASS 10 A
Degree of protection (IP)
IP20
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Foundation Fieldbus
No
With transformer
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for INTERBUS
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Temperature compensated overload protection
Yes
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation power at AC-3, 400 V
0.18kW
Rail mounting possible
No
Supporting protocol for SERCOS
No
Supporting protocol for Data-Highway
No
Supporting protocol for CAN
No
Number of auxiliary contacts as normally open contact
0
Ambient temperature, upper operating limit
55°C
Width
90mm
Depth
185mm
Height
95mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
MSC-R-0,63-M7(230V50HZ)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated operation power at AC-3, 230 V, 3-phase
0.09kW
Rated control supply voltage Us at DC
0 .. 0V
With short-circuit release
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Type of motor starter
Reversing starter
Voltage type for actuating
AC
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
0.6A
Power consumption
1.4W
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
0.63A
Rated conditional short-circuit current, type 2, 400 V
50000A
Overload release current setting
0.4 .. 0.63A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 230 V
50000A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Number of indicator lights
0
Supporting protocol for TCP/IP
Coordination class according to IEC 60947-4-3
Class 2
With fuse
Supporting protocol for SUCONET
External reset possible
Supporting protocol for PROFIBUS
Degree of protection (NEMA)
Other
Number of command positions
0
Suitable for emergency stop
Supporting protocol for ASI
Release class
CLASS 10 A
Degree of protection (IP)
IP20
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
With transformer
Supporting protocol for LON
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SafetyBUS p
Supporting protocol for INTERBUS
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Temperature compensated overload protection
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation power at AC-3, 400 V
0.18kW
Rail mounting possible
Supporting protocol for SERCOS
Supporting protocol for Data-Highway
Supporting protocol for CAN
Number of auxiliary contacts as normally open contact
0
Ambient temperature, upper operating limit
55°C
Width
90mm
Depth
185mm
Height
95mm
From same serie
We use cookies to enhance your experience.