

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Yes
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 - 24V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 400 V
0.18kW
Rated operation current Ie
0.6A
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
0.09kW
Rated conditional short-circuit current, type 2, 230 V
50000A
Overload release current setting
0.4 - 0.63A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Ambient temperature, upper operating limit
55°C
Number of auxiliary contacts as normally open contact
1
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Suitable for emergency stop
No
Type of electrical connection of main circuit
Screw connection
External reset possible
No
Rated operation current at AC-3, 400 V
0.63A
Power consumption
2.6W
Rail mounting possible
No
Number of command positions
0
Temperature compensated overload protection
Yes
Number of auxiliary contacts as normally closed contact
0
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
No
Degree of protection (IP)
IP20
Number of indicator lights
0
Supporting protocol for PROFIBUS
No
Supporting protocol for ASI
No
Supporting protocol for DeviceNet
No
Supporting protocol for INTERBUS
No
Rated conditional short-circuit current, type 2, 400 V
50000A
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for LON
No
Supporting protocol for Modbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
No
With fuse
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
With transformer
No
Supporting protocol for SERCOS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for CAN
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for SafetyBUS p
No
Height
180mm
Depth
95mm
Width
45mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
MSC-D-0,63-M7(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 .. 24V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 400 V
0.18kW
Rated operation current Ie
0.6A
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
0.09kW
Rated conditional short-circuit current, type 2, 230 V
50000A
Overload release current setting
0.4 .. 0.63A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Ambient temperature, upper operating limit
55°C
Number of auxiliary contacts as normally open contact
1
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Suitable for emergency stop
Type of electrical connection of main circuit
Screw connection
External reset possible
Rated operation current at AC-3, 400 V
0.63A
Power consumption
2.6W
Rail mounting possible
Number of command positions
0
Temperature compensated overload protection
Number of auxiliary contacts as normally closed contact
0
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
Degree of protection (IP)
IP20
Number of indicator lights
0
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Supporting protocol for DeviceNet
Supporting protocol for INTERBUS
Rated conditional short-circuit current, type 2, 400 V
50000A
Supporting protocol for Foundation Fieldbus
Supporting protocol for LON
Supporting protocol for Modbus
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
With fuse
Supporting protocol for EtherNet/IP
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
With transformer
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for CAN
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Height
180mm
Depth
95mm
Width
45mm
From same serie
We use cookies to enhance your experience.